Known limitations

  • One home per Home Assistant instance — a single config entry drives one whole-home entity. Per-room bias exists (area band offsets), but rooms don't have independent schedules; use presets + automations for time-based behaviour.
  • Rooms need their own sensors for full local control. A device whose HA area has no temperature sensor is controlled against the home average only.
  • Valve/calibration discovery is name-based. MPC and offset modes find a TRV's number entities by name hints (Zigbee2MQTT/SONOFF defaults, configurable in options); a brand with different naming needs its hints set.
  • MPC learns from history. After install or a learning reset, valve control starts from conservative priors and typically needs a few hours of heating to fit a room's model (watch the MPC learning status sensors).
  • MPC assumes a constant radiator output. The learned model treats heating power at a given valve opening as fixed (it learns one gain). On a weather-compensated hydronic system — most district heating, and condensing boilers with an outdoor-reset curve — the supply-water temperature rises as it gets colder, so the same valve opening emits more heat in harsh weather. MPC captures the increased heat loss (the loss·(room − outdoor) term) but not the increased output; it re-learns gain over a rolling window, so comfort is held by feedback, but expect a worse model fit and weaker preconditioning, with transient over/undershoot when the supply temperature shifts quickly. On such systems offset calibration mode is sometimes the better choice — it lets the valve's own loop modulate against whatever water temperature is present. A repair notice flags a TRV whose MPC model fits persistently poorly.
  • Forecast preconditioning needs an hourly forecast from the configured weather entity, and only ever raises heating — it won't pre-cool.
  • Manual-override detection is heuristic. A takeover is recognised by its trajectory (the device was at the commanded state, then moved away), so two rare races exist: a manual change made while a command is still in flight is read as non-compliance instead (the watchdog's case, no takeover), and a state report landing in the same instant the command itself changes can start a spurious takeover. Both windows are milliseconds wide and the consequences bounded — at worst one device is left alone for the Manual override duration, any interaction with the thermostat reasserts control, and frost protection punches through regardless.
  • Devices must be standard HA climate entities exposing the usual attributes (hvac_modes, current_temperature, min/max). Anything that does is fair game; anything that doesn't isn't.